Accurate Network-Appliance NS0-520 Study Guides Online

Actualtests NS0-520 Questions are updated and all NS0-520 answers are verified by experts. Once you have completely prepared with our NS0-520 exam prep kits you will be ready for the real NS0-520 exam without a problem. We have Updated Network-Appliance NS0-520 dumps study guide. PASSED NS0-520 First attempt! Here What I Did.

Free demo questions for Network-Appliance NS0-520 Exam Dumps Below:

NEW QUESTION 1

You want to use ANA on SUSE Enterprise Linux. Which two components need to be verified in this scenario? (choose two)

  • A. Verify the version of ONTAP
  • B. Verify the version of SUSE Enterprise Linux
  • C. Verify that ALUA must be enabled
  • D. Verify that the ANA driver is installed

Answer: AB

Explanation:
ANA Supportability
NVMe/FC is supported on ONTAP 9.6 or later for the following versions of SLES: SLES15 SP1
SLES15 SP1 host can run both NVMe/FC, & FCP traffic through the same fibre channel initiator adapter ports.
You can find more information on this link:
https://docs.netapp.com/us-en/ontap-sanhost/nvme_sles15_sp1.html#supportability

NEW QUESTION 2

A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme.
In this scenario, what is the problem?

  • A. The SVM data protocol should be set to FC.
  • B. The NVMe namespace is not created.
  • C. A demo license is used.
  • D. Only one NVMe data LIF can be configured per SVM.

Answer: B

NEW QUESTION 3

You are planning on implementing a new SAN on AFF A400 controllers. The data set consists of unique 1 KB files that will be encrypted before being written to the SAN.

  • A. Compaction
  • B. compression
  • C. Deduplication
  • D. Autogrow

Answer: A

Explanation:
A screenshot of a computer Description automatically generated with medium confidence
NS0-520 dumps exhibit

NEW QUESTION 4

Which two scenarios in deploying ONTAP Cloud are supported by the Cloud Manager tool? (Choose two.)

  • A. ONTAP Cloud deployed as an HA pair on IBM Cloud
  • B. ONTAP Cloud deployed as an HA pair on VMware
  • C. ONTAP Cloud deployed as a single instance on Microsoft Azure
  • D. ONTAP Cloud deployed as an HA pair on Amazon Web Services

Answer: CD

NEW QUESTION 5

An administrator is migrating from a third-party's SAN to a newly purchased FAS9000. The administrator decides to use the NetApp Foreign LUN Import (FL1) process.
What must the administrator do for this process to work properly?

  • A. Create multiple igroups for the Initiator ports.
  • B. Create six distinct zones that include specific ports within each zone.
  • C. Zone target ports of source storage with initiator ports of destination storage.
  • D. Make the destination LUN larger than the foreign LUN.

Answer: C

NEW QUESTION 6

You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 LUNs that use under 5000 IOPS are moved to a FAS8200 using the lun move command.
In this scenario, what happens to the data after the LUN is moved? (Choose two.)

  • A. The new written data is not compacted.
  • B. The new written data is compacted.
  • C. The existing data is compacted.
  • D. The existing data is not compacted.

Answer: BD

NEW QUESTION 7

You have implemented FabricPool on your AFF ASA ONTAP 9.8 Cluster. An archived database has become very active, and it requires FabricPool adjustments.
Which two steps are required to address this issue? (Choose two)

  • A. Use the promote cloud-retrieval-policy
  • B. Remove all snapshot copies.
  • C. Set the tiering-policy to none
  • D. Set the space-guarantee on the volume

Answer: AC

Explanation:
Promoting all data from a FabricPool volume to the performance tier.
You can proactively retrieve all data on a FabricPool volume in the Cloud and promote it to the performance tier.
Use the volume modify command to set tiering-policy to none and cloud-retrieval-policy to promote. You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-mgng-stor-tier-fp%2FGUID-45FEF77

NEW QUESTION 8

You have a SAN host that is only sending traffic to an ONTAP cluster using active non-optimized paths. In this scenario, over which network type does the node that is hosting the target LUN receive the
traffic?

  • A. Fibre Channel network
  • B. Cluster network
  • C. ISCSI network
  • D. Intercluster network

Answer: B

Explanation:
The Cluster Network
This is used for traffic that is going between the nodes themselves, such as system information that is being replicated between the nodes. Also, if incoming client data traffic hits a network port on a different
controller than the one which owns the disks, that traffic will also go over the cluster network.

NEW QUESTION 9

NS0-520 dumps exhibit
Which two storage efficiencies have been enabled on the NVMe namespace that is shown in the exhibit? (Choose two.)

  • A. deduplication
  • B. compaction
  • C. compression
  • D. thin provisioning

Answer: B

NEW QUESTION 10

A database administrator needs to ensure that snapshot copies of database files across multiple LUNs are taken at the same point in time. Which action achieves this outcome?

  • A. Create each LUN within the same FlexVol volume
  • B. Create each LUN on the same Fabric Pool aggregate
  • C. Add each LUN volume to the same snapshot schedule
  • D. Create each LUN within the same FlexGroup Volume

Answer: A

Explanation:
We can discard Flexgroup because it only works on NAS Protocols.
We can discard LUNs and Aggregates because snapshots are not taken at that level
Snapshots are taken at volume level
You can find more information on this link:
https://community.netapp.com/t5/ONTAP-Discussions/can-we-creat-multiple-luns-from-same-volume-on-AFF3

NEW QUESTION 11

NS0-520 dumps exhibit
You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN.
Using MAX Data as shown in the exhibit, which two LUN access protocols are supported with this solution? (Choose two.)

  • A. iSCSI
  • B. FCoE
  • C. FC
  • D. NVMe

Answer: D

NEW QUESTION 12

Which two components should be installed to support VMware VMFS6 datastores in an environment with only Ethernet switches? (Choose two)

  • A. V_StorageAttach license
  • B. Host Utilities
  • C. NetApp Virtual Storage Console
  • D. iSCSI licenses

Answer: CD

Explanation:
Installing VSC is the best practice recommended by Netapp when you use VMware and this is an environment with only Ethernet switch, so ISCSI licenses are needed to present LUNs to the Virtual
environment.
You can find more information on this link:
https://docs.netapp.com/us-en/netapp-solutions/pdfs/sidebar/VMware_vSphere_with_ONTAP_Best_Practices.p

NEW QUESTION 13

An administrator needs to connect a new VMware 6.5 cluster to an ONTAP cluster for iSCSl connectivity. Which two steps would accomplish this task? (Choose two.)

  • A. Enable iSCSl adapters on the ESXi hosts.
  • B. Install the Virtual Storage Console for VMware vSphere.
  • C. Configure zoning for the HBAs and the ONTAP data LIFs.
  • D. Configure ALUA on the ONTAP SVM.

Answer: AD

NEW QUESTION 14

You are testing FCP paths failures on a 2-node Netapp AFF All SAN Array and verify that persistent ports are correctly enabled. Before testing, a host sees four optimized paths to a LUN. You perform a
node takeover and re-check the host.
Which statement is true after the node takeover?

  • A. The host sees four optimized paths to the LUN
  • B. The host sees two non-optimized paths and two dead paths to the LUN
  • C. The host sees two optimized paths and two non-optimized paths to the LUN
  • D. The host sees two optimized paths and two dead paths to the LUN

Answer: A

Explanation:
Support for persistent ports
Beginning in ONTAP 9.8, persistent ports are enabled by default on All SAN Arrays (ASAs) that are configured to use the FC protocol. Persistent ports are only available for FC and require zone
membership identified by World Wide Port Name (WWPN).
Persistent ports reduce the impact of takeovers by creating a shadow LIF on the corresponding physical port of the HA partner. When a node is taken over, the shadow LIF on the partner node assumes the
identity of the original LIF, including the WWPNe. Before the status of path to the taken over node is changed to faulty, the shadow LIF appears as an Active/Optimized path to the host MPIO stack, and I/O is
shifted. This reduces I/O disruption because the host always sees the same number of paths to the target, even during storage failover operations.
You can find more information on this link:
https://docs.netapp.com/allsan/index.jsp?topic=%2Fcom.netapp.doc.dot-asa-config%2FGUID-646B3CFD-9E00

NEW QUESTION 15

A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 that is running ISCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.

  • A. Volume move
  • B. Volume rehost
  • C. Volume reallocation
  • D. Aggregate reallocation

Answer: B

Explanation:
Moving a Volume will only work if you are doing it within the same SVM
Volume Reallocation is used when you add new disks to an aggregate and you need to redistribute the data Aggregate Reallocation can be used only when you are moving data from an AFF filer to another AFF filer Rehosting a volume from one SVM to another SVM
Volume rehost enables you to reassign NAS or SAN volumes from one storage virtual machine (SVM, formerly known as Vserver) to another SVM without requiring a SnapMirror copy. The volume rehost procedures depend upon the protocol type and the volume type. Volume rehost is a disruptive operation for data access and volume management.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-vsmg%2FGUID-84308166-6872

NEW QUESTION 16

You are a system administrator and responsible for a Netapp AFF A800 2-node ONTAP 9.8 cluster that is used only for SAN. Your SAN uses FC and FCoE on the same Cisco switches. You want to add
NVMe from the ONTAP controller to the same Cisco fabric. Which two statements are correct in this scenario? (choose two)

  • A. The same SVM can serve both the FC and the FCoE protocols
  • B. The same SVM cannot serve both the FC and the NVMe protocols
  • C. FCoE and NVMe can share the same physical port
  • D. FC and NVMe can share the same 32 GB physical port

Answer: AD

Explanation:
FC and FC-NVMe can share the same 32 Gb physical port
The same SVM can serve both FC and NVMe protocols using the same physical infraestructure wiith different LIFs
FCoE and NVMe can NOT share the same infraestructure, they go trough different physical hardware
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanconf%2FGUID-7D5EA321-97

NEW QUESTION 17

You need to gather information from the host systems that will be attached to the NetApp storage system using either FC or iSCSI. This information includes operating system version, patch levels, open bus slots, and cards in bus slots. What other information must you gather from the host systems?

  • A. bus type (PCIe and/or PCI-x) and video adapters
  • B. memory in system and Ethernet ports (both used and free)
  • C. bus type (PCIe and/or PCI-x)and Ethernet ports (both used and free)
  • D. bus type (PCIe and/or PCI-x) and Serial ports (both used and free)

Answer: C

NEW QUESTION 18

Which topology allows for guaranteed maximum network performance for iSCSI?

  • A. isolated VLAN network
  • B. MetroWAN network
  • C. direct connect
  • D. WAN network

Answer: C

NEW QUESTION 19

Which two components must be verified for a supported NetApp SAN confutation? (Choose two.)

  • A. host memory
  • B. host GPU
  • C. host multipath
  • D. host bus adapter

Answer: CD

NEW QUESTION 20

A customer has an existing 8-node cluster that consists of six FAS2650 nodes and two FAS2554 nodes. The customer wants to expand the cluster by adding two AFF A220 nodes.
Which resource would be used to determine whether this configuration is supported?

  • A. Interoperability Matrix Tool (IMT)
  • B. Config Advisor
  • C. OneCollect
  • D. Hardware Universe (HWU)

Answer: B

NEW QUESTION 21
......

P.S. Thedumpscentre.com now are offering 100% pass ensure NS0-520 dumps! All NS0-520 exam questions have been updated with correct answers: https://www.thedumpscentre.com/NS0-520-dumps/ (234 New Questions)