Cisco 300-175 Study Guides 2021

We provide which are the best for clearing 300-175 test, and to get certified by Cisco DCUCI Implementing Cisco Data Center Unified Computing (DCUCI). The covers all the knowledge points of the real 300-175 exam. Crack your Cisco 300-175 Exam with latest dumps, guaranteed!

Online 300-175 free questions and answers of New Version:

NEW QUESTION 1
When configuring roles in the Cisco UCS C-Series, which role should be assigned for a person who must be allowed to power on the server and install a hypervisor using virtual media, but not allowed to configure other Cisco Integrated Management Controller settings?

  • A. VM admin
  • B. user
  • C. admin
  • D. read-only

Answer: B

NEW QUESTION 2
300-175 dumps exhibit
300-175 dumps exhibit

    Answer:

    Explanation: The cluster will switch fabric interconnect b from subordinate to lead or primary.

    NEW QUESTION 3
    While configuring VM-FEX for Hyper-V, the virtual switch does not show up when you add the host with the port-profile management snap-in. Which statement describes the most likely cause?

    • A. SR-IOV is not enabled for the virtual switch inside Hyper-V.
    • B. Cisco Nexus 1000v is not enabled for the virtual switch.
    • C. Hyper-V requires Cisco UCS Manager to utilize Cisco Discovery Protocol on the vNIC profile.
    • D. An active VM is not associated with the port profile.
    • E. VM-FEX does not work with Hyper-V.
    • F. VM-FEX has been configured on the Catalyst switch but not in System Center yet.

    Answer: A

    NEW QUESTION 4
    Which scheduling option sets the number of tasks that can be run?

    • A. max number of concurrent tasks
    • B. max changes
    • C. max number of tasks
    • D. max configuration requests

    Answer: C

    NEW QUESTION 5
    When implementing iSCSI boot, which prerequisite is true?

    • A. Each iSCSI initiator must be on the same IP subnet
    • B. The OS must be iBFT compatible
    • C. The boot parameters must be configured in the Global boot policy
    • D. There are no licensing requirements for the storage array

    Answer: B

    NEW QUESTION 6
    Which policy is used to update adapter firmware?

    • A. adapter policy
    • B. host firmware policy
    • C. management firmware policy
    • D. network control policy

    Answer: B

    NEW QUESTION 7
    Which command sequence in the Cisco UCS C-Series rack server CLI sends tech support data to a TFTP server?

    • A. ucs-c250 / # scope cimcucs-c250 /cimc # scope tech-supportucs-c250 /cimc/tech-support # set path default.tar.gzucs-c250 /cimc/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /cimc/tech-support *# commit
    • B. ucs-c250 / # scope systemucs-c250 /system # scope tech-supportucs-c250 /system/tech-support # set path default.tar.gzucs-c250 /system/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /system/tech-support *# commit
    • C. ucs-c250 / # scope supportucs-c250 /support # scope tech-supportucs-c250 /support/tech-support # set path default.tar.gzucs-c250 /support/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /support/tech-support *# commit
    • D. ucs-c250 / # scope faultucs-c250 /fault # scope tech-supportucs-c250 /fault/tech-support # set path default.tar.gzucs-c250 /fault/tech-support *# set tftp-ip 192.168.70.45 ucs-c250 /fault/tech-support *# commit

    Answer: A

    Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-1-2/b_Cisco_CIMC_CLI This example creates a support data file and transfers the file to a TFTP server:
    Server# scope cimc
    Server /cimc # scope tech-support
    Server /cimc/tech-support # set tftp-ip 10.20.30.41
    Server /cimc/tech-support *# set path /user/user1/supportfile Server /cimc/tech-support *# commit Server
    /cimc/tech-support # start
    Reference:
    https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/cli/config/guide/1-1-2/b_Cisco_CIMC_CLI

    NEW QUESTION 8
    Refer to the exhibit.
    300-175 dumps exhibit
    How does a server acquire a UUID?

    • A. from the UUID burned into the hardware
    • B. from a UUID pool named derived
    • C. manually by a user when the server boots
    • D. by padding the MAC address with leading zeros

    Answer: A

    NEW QUESTION 9
    Which consideration must be made while utilizing the UEFI boot mode?

    • A. Legacy boot modes cannot be used on the same server.
    • B. This mode applies only to models before the M3.
    • C. The service profile cannot be disassociated without decommissioning the blade.
    • D. This mode replaces the UEFI shell typically available as a boot fallback.

    Answer: A

    NEW QUESTION 10
    300-175 dumps exhibit

      Answer:

      Explanation: 300-175 dumps exhibit

      NEW QUESTION 11
      Which two items can you provision in a vHBA Template? (Choose two.)

      • A. Max Data Field Size
      • B. SCSI I/O Queues
      • C. FCoE VLAN
      • D. vHBA Interrupt Mode
      • E. Stats Threshold Policy
      • F. FLOGI Timeout

      Answer: AE

      NEW QUESTION 12
      When upgrading a standalone Cisco UCS C-Series server, which method is correct?

      • A. direct upgrade on all components
      • B. Cisco Hardware Upgrade Utility
      • C. Cisco Host Upgrade Utility
      • D. Cisco Server Upgrade Utility

      Answer: C

      NEW QUESTION 13
      The Cisco UCS administrator has the chassis discovery policy set to "2-link". The administrator connects a new chassis to the Cisco UCS 6200 Series Fabric Interconnects using four links. Which option about link utilization is true?

      • A. The Cisco UCS will use two links until the chassis is reacknowledged, after which it will use all four links.
      • B. The Cisco UCS will use all four links for discovery.
      • C. The Cisco UCS will use only two link
      • D. The other two links are unusable.
      • E. The Cisco UCS will use only two link
      • F. However, the administrator can manually pin traffic to the extra links by using service profiles.

      Answer: A

      NEW QUESTION 14
      In a standalone Cisco UCS C-Series server, which recommendations can be used to upgrade the BIOS?

      • A. Cisco IMC
      • B. Cisco UCS Manager
      • C. iFlash32 Utility
      • D. Flash ROM Utility
      • E. EFI Interface
      • F. Cisco Host Upgrade Utility
      • G. USB Flash Utility

      Answer: F

      NEW QUESTION 15
      You must define a workload using Cisco UCS Manager. Drag and drop the workload definition tasks from the left into the correct order on the right.
      300-175 dumps exhibit

        Answer:

        Explanation: Define organizational hierarchy Define Pools
        Configure Adapters
        Configure Service Profile Templates Configure Server Policies

        NEW QUESTION 16
        You have server that has a Cisco UCS CAN. A service profile that has a vNIC and a VHBA is mapped to fabric A. The vNIC is configured to use VLAN 10. VLAN 10 is the native VLAN for the vNIC. The vHBA is configured to use VSAN 2. Which description of the configuration is true?

        • A. VSAN 2 can be configured by using VLAN 10 as the FCoE VLAN ID.
        • B. VSAN 2 can read traffic on VLAN 5.
        • C. VLAN 10 and VSAN 2 must use the same ID.
        • D. VSAN 2 can be mapped to their VLANs in fabric A.

        Answer: A

        NEW QUESTION 17
        Which destination(s) are valid for syslog messages for a Cisco UCS Fabric Interconnect?

        • A. the log, the monitor and syslog queue
        • B. a file
        • C. the console and log only
        • D. the console, the monitor, and a file

        Answer: D

        Explanation: http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/ucsm_syslog/b_Monitoring_Cisco_UCSM_Us

        NEW QUESTION 18
        Scenario
        In this scenario, you will refer to screenshots about Cisco UCS B-Series servers and UCS Manager. Instructions
        To access the multiple-choice questions, click on the numbered boxes on the left of the top panel. There are four multiple-choice questions with this task. Be sure to answer all four questions before selecting the Next button.
        300-175 dumps exhibit
        300-175 dumps exhibit
        300-175 dumps exhibit
        Refer to the Exhibit 4 screenshot of the UCS Manager. Which item can only be configured in the Storage Cloud?

        • A. iQN Pools
        • B. Storage FC Clinks
        • C. Port Channels
        • D. VSANs
        • E. Zoning

        Answer: D

        Explanation: Reference:
        http://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucsinfrastructure-ucs-manager-software/1

        NEW QUESTION 19
        Which statement about fabric failover for Fibre Channel communication is true?

        • A. You can enable hardware Fibre Channel failover.
        • B. Cisco UCS load balances Fibre Channel traffic between the two fabrics.
        • C. You must use a Fibre Channel multipath I/O driver.
        • D. You do not have to use anything.

        Answer: C

        Explanation: Reference:
        https://supportforums.cisco.com/t5/unified-computing-system/san-multi-pathing-best-practices/td-p/1545645 https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/unified-computing-system/116471-confi https://kb.netapp.com/support/s/article/how-to-verify-windows-fibre-channel-configurations-with-multipathing-i

        Recommend!! Get the Full 300-175 dumps in VCE and PDF From Certleader, Welcome to Download: https://www.certleader.com/300-175-dumps.html (New 349 Q&As Version)